TY  - JOUR
T1  - Improved of Frequency Stability Response using the High Speed Valve Control
(HSVC) of the Micro Hydro Power Plant
AU - Nojeng, Syarifuddin AU - Yunus, Shiddiq AU - Murniati, R.A. Reny AU - , Sugianto 
JO  - International Journal of Electrical and Power Engineering
VL  - 13
IS  - 1
SP  - 1
EP  - 4
PY  - 2019
DA  - 2001/08/19
SN  - 1990-7958
DO  - ijepe.2019.1.4
UR  - https://makhillpublications.co/view-article.php?doi=ijepe.2019.1.4
KW  - hydro power plant
KW  -HSVC method
KW  -Frequency stability response
KW  -renewable energy
KW  -frequency
KW  -appropriate
AB  - Micro-Hydro Power Plant (MHPP) is one of popular renewable based power plants that appropriate
to be installed in developing countries such as Indonesia due to its stability, efficient operation and economic
point of view. Frequency stability of power plant systems refers to the ability of generator to maintain the steady
frequency during and post faults and rapid dynamic load. In order to keep the stability of power system
frequency from fluctuations, generating units change their power output automatically according to the change
of the system frequency or load through balancing of the active power with the loads. To keep the stability
frequency on MHPP, active power fast control is employed in this study and all the system of MHPP and the
frequency control are carried out and simulated extensively using MATLAB/Simulink. With the active power
control through fast valving mechanism using HSVC method, duration of stability frequency response is faster
compared to the system without fast control.
ER  - 