TY  - JOUR
T1  - The Influence of Resin Matrix on The Water Sorption of Fiber-Reinforced Composites for DENTAL Use
AU - Pekka Matinlinna, Jukka AU - Siswomihardjo, Widowati AU - Sunarintyas, Siti 
JO  - Journal of Engineering and Applied Sciences
VL  - 11
IS  - 12
SP  - 2678
EP  - 2682
PY  - 2016
DA  - 2001/08/19
SN  - 1816-949x
DO  - jeasci.2016.2678.2682
UR  - https://makhillpublications.co/view-article.php?doi=jeasci.2016.2678.2682
KW  - Fiber-reinforced composite
KW  -bis-GMA
KW  -HDDMA
KW  -water sorption
KW  -comparable
KW  -monomer
AB  - Bis-GMA as resin matrix of FRC is widely used in dentistry is reported as cytotoxic. The resin matrix
studied, 1,6 hexanediol dimethacrylate (HDDMA) has similar reactive groups than bis-GMA is not known as
carcinogens. Clinically, resin matrix absorbs water and lower the material&#146;s strength. This study investigated
the water sorption of FRC based on HDDMA monomer compared to bis-GMA. Fifteen specimens (2.0 mmx
2.0&times;25.0 mm) were divided into (Group-1): 78.4 wt-% HDDMA+19.6 wt-% MMA+1.0 wt-% CQ+1.0 wt-% CEMA,
(group-2): 49.0 wt-% HDDMA+49.0 wt-% MMA+1.0 w-% CQ+1.0 wt-% CEMA and (group-3): 78.4 wt%
bis-GMA+19.6 wt-% MMA+1.0 wt-% CQ+1.0 wt-% CEMA. Each specimen contained two E-glass fiber rovings.
The specimens were light-cured and immersed in distilled water for 21 days. The differences in weights, beforeafter
immersion were recorded. Group-1 proved the lowest average (0.004%), followed by group-3 (0.003%) and
group-2 (0.01%). There was a significant difference among all groups (p<0.05) while LSD showed a significant
difference between groups 1 and 2 (p<0.05) but no significant difference between groups 1 and 3 (p>0.05). It
is concluded that FRC based on HDDMA matrix (group-1) is comparable to bis-GMA (group-3) for its water
sorption.
ER  - 