@article{MAKHILLJEAS201813815978,
    title = {Harmonic Distortion Improving of Insulator String Model by Nonlinear
Resistive under Polluted Condition},
    journal = {Journal of Engineering and Applied Sciences},
    volume = {13},
    number = {8},
    pages = {1986-1990},
    year = {2018},
    issn = {1816-949x},
    doi = {jeasci.2018.1986.1990},
    url = {https://makhillpublications.co/view-article.php?issn=1816-949x&doi=jeasci.2018.1986.1990},
    author = {Tharin and},
    keywords = {high voltage,ESDD,nonlinear model,harmonic order,Insulator model,current},
    abstract = {Designing of power distribution system must be simulated the flashover occurring in any case. To
flashover prediction by leakage current observing, the harmonic distortion of current waveform is one factor
that be considered. This study focused on insulator model improving to inclusive of harmonic distortion of
leakage current in different pollution level by nonlinear resistive from arcing gap model as structure of insulator.
So, the aimed to compare to the results of the primitive model and the nonlinear model that can be applied from
arc characteristics divided in two parts. The part of measurement include resistance collecting and voltage
current relating of insulators which were treated in different pollution levels as to very light, light, moderate and
heavy pollution by different NaCl addition through soaking. The part of simulation of a string insulator with
6 series insulator by both of model. The model including nonlinear resistive can significantly generated more
harmonic in order 3rd and 5th where higher pollution level different from primitive model. However, the model
must be developed to generate more harmonic distortion.}
    }