@article{MAKHILLJEAS2017121914860,
    title = {Analysis of 1.2 kW Wind Power Generation using 24 V DC Bus with Energy
Storage System for Hybrid Solar Thermal-Wind Power Generation},
    journal = {Journal of Engineering and Applied Sciences},
    volume = {12},
    number = {19},
    pages = {5043-5049},
    year = {2017},
    issn = {1816-949x},
    doi = {jeasci.2017.5043.5049},
    url = {https://makhillpublications.co/view-article.php?issn=1816-949x&doi=jeasci.2017.5043.5049},
    author = {Suroso,Priswanto and},
    keywords = {Wind power,electricity,power converter,energy production,Indonesia,Purbalingga},
    abstract = {This study presents design of 1.2 kW wind power generation using 24 V DC bus system equipped
with batteries as energy storage system to be installed in Purbalingga City, Jawa Tengah, Indonesia.
Two 300 W wind Turbines and a 600 W wind Turbine are used to capture the wind energy to be converted into
electricity. The wind power is designed to be integrated with thermal solar power generation as a hybrid power
generation system. Battery charge controllers are applied to control the energy stored into the batteries. The
24 DC voltage of the batteries system are convert into Alternating Current (AC) to supply the AC power load
by using power inverters. Some measurement and experimental test results of the wind power system installed
in Purbalingga City, Jawa Tengah are presented in the study to explore the performance of the wind power
system. The annual energy production analysis shown that the highest energy production was achieved on
August with the total energy production 822 kWh/year.}
    }